The platform behind every ParaNano product

One Technology
Two Products

Bio-Z® is ParaNano's passive, non-electronic nanofiber platform, the core materials technology behind both WoundCue™ and WoundSentinel™. Designed to be used with a standard dressing, it is intended to provide a color change corresponding to elevated bacterial lipase activity, read by the naked eye, with no batteries, readers, or electronics.

*This device has not been FDA-cleared or approved for in vitro diagnostic use and is not available for sale. Describes a device under development. Intended as a qualitative result; does not quantify microorganism load or identify organisms. Based on laboratory (bench) testing; laboratory results may not predict clinical performance.

WoundCue Bio-Z® color-changing nanofiber membrane

Our Partners

UMass Lowell University of Central Oklahoma University of Manitoba OSU New Product Development Center National Science Foundation / NSF I-Corps ARM Venture Solutions Veterans Way Prime Path Medtech
How it works

One core technology. A color change you can see.

Bio-Z® is not a product you buy, it's the core sensing technology behind ParaNano's products. The functionalized nanofiber membrane is designed to be used with a standard dressing. In bench testing, as bacterial lipase activity rises, its chemistry responds, producing a visible, qualitative color change for interpretation by a healthcare professional.

  1. 1

    Integrate

    A thin Bio-Z® nanofiber layer is used with the standard wound dressing, designed to fit existing wound-care protocols without added steps.

  2. 2

    React

    In bench testing, the membrane responds to bacterial lipase activity. No reagents, power, or connectivity required.

  3. 3

    Signal

    The response surfaces as an at-a-glance, qualitative color change, intended for interpretation by a healthcare professional alongside clinical and laboratory findings.

WoundCue Bio-Z® nanofiber membrane
0
Power or connectivity required
0
Products built on the Bio-Z® platform
All
Care settings, clinical, home, and austere
Built on Bio-Z®

Two products, one core technology.

WoundCue™ and WoundSentinel™ are the products; Bio-Z® is the platform they share, the same core technology, applied two different ways. See the laboratory evidence ›

WoundCue™

For clinical & home care

WoundCue™ applies the Bio-Z® platform to everyday wound care, an investigational, battery- and wire-free colorimetric product that shows a color change corresponding to elevated bacterial lipase activity, read by the naked eye.

ColorimetricNo electronicsInvestigational
Explore WoundCue™
WoundSentinel™

For the field & austere care

A field/military variant of the Bio-Z® platform in development (TRL-6), designed for austere environments, the same passive, non-electronic color-changing approach.

In developmentNon-electronicMilitary & austere
Explore WoundSentinel™
“By the time we see fever, new spasticity, or an autonomic dysreflexia episode, the infection is usually deep.”
Wound-care nurse  ·  VA spinal-cord injury unit

From ParaNano’s voice-of-customer research (small voluntary sample, n=14); a clinician-reported need, not device performance. WoundCue™ is investigational and has not been FDA-cleared or approved.

The clinical challenge

Why wound monitoring is hard.

A recognized challenge

Early awareness of wound deterioration is a recognized clinical challenge, and routine infection assessment can be subjective and intermittent.1

The role of enzymes

Bacterial lipase is an enzyme produced by wound-relevant bacteria, and certain microbial enzymes can rise with increasing microbial load.2

A stated clinician need

Objective, at-a-glance information is a stated clinician need, the problem space ParaNano's materials science is being developed to help address.1

Educational; based on published literature and not attributed to WoundCue™ performance. 1. Swanson T, et al. IWII Wound Infection in Clinical Practice, 2022 update. J Wound Care. 2022;31(Sup12):S10–S21.  2. Gácser A, et al. Infect Immun. 2007;75(10):4710–4718.

Get in touch

See what the Bio-Z® platform could bring to your wound-care program.

Investigational today, and advancing fast. Talk with our team about product information, defense programs, and partnership opportunities.

Read our newsletter

The journey toward a healthier tomorrow.

At ParaNano, we're pioneering the future of wound care, rooted in innovation, compassion, and a deep commitment to patient outcomes. Join us for updates, breakthroughs, and milestones.

All News

Subscribe for updates

Milestones, breakthroughs, and news, straight to your inbox.

WoundCue™ · Built on Bio-Z®

Bio-Z®, applied to everyday wound care.

WoundCue™ brings the Bio-Z® platform to everyday care, an investigational, battery- and wire-free colorimetric product that shows a color change corresponding to elevated bacterial lipase activity, read by the naked eye and interpreted by a healthcare professional across home and clinical settings.

The clinical challenge

What we’re fighting.

01

The pathogens behind wound decline

Bacteria and fungi, including Staphylococcus aureus, Pseudomonas aeruginosa, and Candida auris, can escalate wound severity. In laboratory testing, WoundCue™ is designed to show a qualitative color change from its baseline yellow in response to elevated bacterial lipase activity.

02

The cost of complications

Unaddressed bacterial and fungal growth is associated with infection, biofilm formation, and delayed healing. A clear, at-a-glance indicator is intended to aid assessment. It does not detect, diagnose, or rule out infection.

03

Support for patients and care teams

WoundCue™ is being developed to give clinicians, caregivers, and patients a passive, power-free visual cue that supports, not replaces, clinical judgment.

*Investigational device under development; not FDA-cleared and not available for sale. Based on laboratory (bench) testing; laboratory results may not predict clinical performance. Intended to aid in the assessment of wound infection; not to detect, diagnose, confirm, or rule out infection.

At a glance

A color change you can read without instruments.

WoundCue™ places a thin Bio-Z® nanofiber layer inside a familiar foam-and-film dressing. No wires, no battery, no reader, the dressing itself carries the color change.

ColorimetricNo powerSingle-useHome & clinic
Status
Investigational, under development
Regulatory pathway
Pursuing an FDA Class II IVD pathway
Interpretation
Healthcare-professional interpreted
See it in action

The dressing, layer by layer.

Illustrative construction. Investigational; not FDA-cleared.

How it’s applied

Applied over the dressing, in three steps.

1
An island foam dressing placed on the wound

An island foam dressing is placed on the wound.

3 in (7.6 cm)
2
WoundCue placed on top of the foam dressing

The WoundCue™ is placed on the foam.

2 cm × 2 cm
3
Transparent film dressing applied over the top, adhering to intact skin

A transparent film dressing is placed on top, extending beyond the foam and adhering to intact skin for a secure, waterproof seal.

6.0 × 7.0 cm (2 3/8 × 2 3/4 in)

Then monitor for a color change. If WoundCue™ changes color, advise the patient to contact a healthcare professional; interpret in conjunction with clinical and laboratory findings. Remove and replace at the standard dressing change or at 72 hours, whichever comes first.

Investigational device under development; not FDA-cleared and not available for sale. Summary of the Instructions for Use. Follow the product IFU. Intended to aid in the assessment of wound infection; not to detect, diagnose, confirm, or rule out infection.

See the concept

From baseline to a visible signal.

An illustration of the qualitative color change Bio-Z® is designed to produce in response to elevated bacterial lipase activity in laboratory testing.

A passive, at-a-glance change.

At baseline the insert reads yellow. In laboratory testing, elevated bacterial lipase activity drives the membrane away from that baseline, and any color change from the baseline yellow is the indication, for interpretation by a healthcare professional, not a measurement or diagnosis. Shown here as an illustrative, looping animation.

Baseline (yellow)Color change
Baseline

*Illustrative only; appearance varies with lighting and conditions. This device has not been FDA-cleared or approved for in vitro diagnostic use and is not available for sale. Describes a device under development. Intended as a qualitative result; does not quantify microorganism load or identify organisms. Based on laboratory (bench) testing; laboratory results may not predict clinical performance.

How to read it

Integrate, react, signal.

1

Apply as usual

WoundCue™ fits standard wound-care workflow. It is applied with the standard dressing, so there are no extra devices or readers.

2

Let it monitor

Between changes, the passive membrane responds to bacterial lipase activity in laboratory testing, continuously and without power.

3

Read at a glance

A visible color change is intended for interpretation by a healthcare professional alongside clinical and laboratory findings.

*This device has not been FDA-cleared or approved for in vitro diagnostic use and is not available for sale. Describes a device under development. Intended to aid in the assessment of wound infection; not to diagnose, confirm, or rule out infection. Based on laboratory (bench) testing; laboratory results may not predict clinical performance.

Why it matters

Designed to fit how care already works.

WoundCue™ is being developed to fit seamlessly into everyday wound care, a clear, passive visual cue intended to support clinicians, caregivers, and patients, not replace clinical judgment.

01

Seamless integration

Potential to fit existing wound-care protocols.

02

A bacterial lipase-anchored signal

A visible, qualitative color change from the baseline yellow in response to elevated bacterial lipase activity in laboratory testing, intended to aid assessment, not to detect, diagnose, or predict infection.

03

No connectivity required

Just place and observe. The goal is a cue that is visible, intuitive, and usable across care settings, including rural and remote environments.

04

Minimal training

Designed to be user-friendly and suitable for caregivers, patients, and healthcare providers of all skill levels.

05

Passive and continuous

Between dressing changes, the membrane responds to bacterial lipase activity in laboratory testing, surfacing a qualitative color change for interpretation by a healthcare professional alongside clinical findings.

WoundSentinel™ · Built on Bio-Z®

A field variant in development.

WoundSentinel™ is a field/military variant of the Bio-Z® platform in development (TRL-6), designed for austere environments, the same passive, non-electronic color-changing approach, with no batteries, readers, or electronic signature. Unlike WoundCue™, which is used with a standard dressing, WoundSentinel™ integrates the Bio-Z® sensing layer with a transparent film dressing in a single, ready-to-apply format.

The field challenge

What we’re fighting.

01

Infection risk, far from care

In austere and resource-limited settings, bacteria and fungi, including Staphylococcus aureus, Pseudomonas aeruginosa, and Candida auris, can escalate wound severity when evacuation and laboratory access are delayed. WoundSentinel™ carries the Bio-Z® sensing layer, designed to show a qualitative color change from its baseline yellow in response to elevated bacterial lipase activity in laboratory testing.

02

The cost in prolonged field care

When care is delivered far from a lab, unaddressed bacterial and fungal growth is associated with infection, biofilm formation, and delayed healing. A clear, at-a-glance visual cue is intended to aid assessment. It does not detect, diagnose, or rule out infection.

03

Built for the point of care in the field

Developed under Defense Health Agency (DHA) SBIR contracts, WoundSentinel™ is a passive, power-free variant in development for austere and remote settings (no reagents, power, or connectivity required), intended to support medics and clinicians, not replace clinical judgment.

*Investigational device under development; not FDA-cleared and not available for sale. Based on laboratory (bench) testing; laboratory results may not predict clinical performance. Intended to aid in the assessment of wound infection; not to detect, diagnose, confirm, or rule out infection.

Built for the field

Designed for prolonged field care.

WoundSentinel™ is designed to bring the passive, non-electronic Bio-Z® approach into austere settings where evacuation may be delayed and laboratory access is limited. Its development is informed by prolonged field care considerations.

In developmentNon-electronicAustere environmentsMilitary
WoundSentinel assembled dressing with the Bio-Z nanofiber insert on a transparent film
Maturity
TRL-6 (in development)
Funding
DHA Direct-to-Phase-II SBIR
Status
Investigational, under development
WoundCue™ vs. WoundSentinel™

One platform, two applications.

Both are built on Bio-Z®. The difference is the environment each is engineered for.

WoundCue™Everyday careWoundSentinel™Field · in development
Primary settingHome & clinical careAustere / field environments (in development)
Form factorColorimetric nanofiber membraneField variant (in development)
IndicationPassive, power-free color change corresponding to elevated bacterial lipase activity (laboratory testing)
Power / connectivityNone required
StatusInvestigational; pursuing an FDA Class II IVD pathwayTRL-6; DHA Direct-to-Phase-II SBIR

*This device has not been FDA-cleared or approved for in vitro diagnostic use and is not available for sale. Describes a device under development. Forward-looking; development and regulatory outcomes and timing are not guaranteed. Based on laboratory (bench) testing; laboratory results may not predict clinical performance.

A closer look

The WoundSentinel™ field variant.

Actual photographs of the assembled field variant, the Bio-Z® nanofiber insert on a transparent film, and the sterile trial pouch.

WoundSentinel assembled dressing
Assembled dressing
Top-down view of the WoundSentinel Bio-Z insert on film
Bio-Z® insert on film
WoundSentinel sterile trial pouch and dressing
Sterile trial pouch

*Product photographs of an investigational device under development; labeled for trial use, not for patient use. Not cleared or approved for sale or clinical use.

“Most of my patients live an hour or more from the clinic. Many live alone and can’t feel or see the bottom of their own foot. Between weekly visits, nobody is really looking at the wound.”
Wound-care clinician  ·  VA amputation clinic

From ParaNano’s voice-of-customer research (small voluntary sample, n=14); a clinician-reported need, not device performance. WoundSentinel™ is investigational and has not been FDA-cleared or approved.

Why it matters

Designed for care in the field.

WoundSentinel™ is being developed for care delivered far from a lab, a passive, power-free visual cue intended to support medics and clinicians in austere and remote settings, not replace clinical judgment.

01

Field-ready integration

The Bio-Z® sensing layer is integrated with a transparent film dressing, with the potential to fit existing field wound-care practices.

02

A bacterial lipase-anchored signal

A visible, qualitative color change from baseline in response to elevated bacterial lipase activity in laboratory testing, intended to aid assessment, not to detect, diagnose, or rule out infection.

03

No power or connectivity

No power, reagents, or connectivity required. Just place and observe. The goal is a cue usable in austere and remote environments.

04

Minimal training

Designed to be user-friendly and suitable for medics, clinicians, and providers of all skill levels.

05

Passive and continuous

Between dressing changes, the Bio-Z® membrane responds to bacterial lipase activity in laboratory testing, surfacing a qualitative color change for interpretation by a provider.

Science & evidence

The science behind Bio-Z®.

Everything below comes from ParaNano's own laboratory (bench) and in-vitro validation reports on the Bio-Z® color-changing nanofiber membrane. These results characterize how the material behaves under controlled conditions. They are not clinical performance, and the products remain investigational.

How we test

Controlled bench & in-vitro methods.

Bio-Z® is evaluated against defined, repeatable laboratory conditions, measured bacterial lipase activity, controlled microbial loads, buffers, salts, and proteins across a range of pH. Studies look at how, and how selectively, the membrane produces a qualitative color change.

Because these are bench and in-vitro studies, they describe material behavior under controlled conditions and may not predict clinical performance.

Zoom into the actual electrospun Bio-Z® nanofiber membrane.

Signal basis
Elevated bacterial lipase activity
Response threshold (bench)
~10⁴–10⁵ CFU/mL load
Read method
Naked-eye, qualitative
In the lab

Made and measured in-house.

Weighing polymer on a laboratory balance
Weighing polymer
Preparing the polymer solution in a fume hood
Solution prep
Drawing the electrospinning solution by pipette
Spinning solution
Nano-morphology

A characterized nanofiber membrane.

Scanning electron microscopy characterized the electrospun membrane (produced with 4% citric acid, 1-hour spin). Across samples, the membrane showed a uniform fibrous structure with a measured thickness of roughly 80–200 µm.

08020025080–200 µmmembrane thickness (µm)

Measured membrane thickness range. Fiber diameter assessed over n>100 fibers.

0h1h2h3h4h5h6h5 h target10 µL20 µL>5h30 µLminimum>5h50 µL>5h100 µL

Time the membrane stayed wet by applied solution volume. 10–20 µL dried within ~2 h; 30 µL and above stayed wet beyond the 5-hour target.

Wettability

Enough fluid for a reliable reaction.

To interact consistently with bacterial lipase, the membrane needs to stay wet. In bench testing, 10–20 µL dried within about two hours, while 30 µL and above kept the membrane wet for over five hours. Eight additional samples at 30 µL all remained wet for the full five hours, establishing 30 µL as the minimum working volume.

Response to bacteria

A visible color change in the presence of wound bacteria.

In bench testing against three common wound bacteria (MRSA, E. coli, and P. aeruginosa, at roughly 10⁵ CFU/cm²), the membrane changed from its baseline yellow within five hours, while control samples (no bacteria) stayed yellow. Any color change from the baseline yellow is the indication; the change observed in this study was toward green. These results characterize the material's response in the laboratory; they do not detect, diagnose, or confirm infection.

T = 0T = 5 hControl (no bacteria)→P. aeruginosa→E. coli→MRSA→

Color change from baseline by sample. Bacteria samples changed from the baseline yellow. The observed shift was toward green; control unchanged.

400450500550600650700wavelength (nm)control ~550response ~525

Spectrophotometry characterized the observed change, a move away from the control's baseline yellow (~550 nm) toward the green region (~525 nm), with negative a* values.

*Intended as a qualitative result; does not quantify microorganism load or identify organisms. Based on laboratory (bench) testing; laboratory results may not predict clinical performance.

Selectivity

It responds to bacterial lipase, not to everyday wound chemistry.

Across 56 bench samples, the membrane produced no color change under physiological pH (4–8) or in the presence of common ions (Na⁺, Mg²⁺, K⁺; 5–150 mM), a wide range of salts, or non-bacterial proteins (FBS, BSA). A change occurred only at non-physiological pH 11. This supports that the response tracks bacterial lipase activity rather than ions, salts, or proteins typically present at a wound.

Bacterial lipase activity, responds Common ions, no response Salts, no response Non-bacterial proteins, no response
pH 4.0pH 7.0pH 8.0pH 11.0AWFPBSTrisTricineBicineMESHEPES

Color response across buffers and pH. No change at physiological pH 4–8; change only at pH 11.

No color changeColor change
0%25%50%75%100%100% = through foam (fail)avg 30%35%S130%S220%S325%S440%S5

Dye migration through the foam by sample. None migrated fully through; average 30%, maximum 40% of foam thickness, all five samples passed.

Leaching & safety

The dye stays in the foam.

A dye-migration study found that the manufacturing dye did not migrate through the foam in any of five samples (average 30%, maximum 40% of foam thickness); all passed. Cytotoxicity, irritation, and sensitization testing were completed, and the material was non-cytotoxic in testing.

Safety & quality

Built to recognized standards.

Biocompatibility

Biocompatibility testing conducted per ISO 10993, with non-cytotoxic results in testing.

Sterilization

The sterilization process has been validated for the current configuration.

Quality system

Developed under a quality management system aligned to ISO 13485 and 21 CFR 820, with design and manufacturing controls.

Peer-reviewed research

The published science behind Bio-Z®.

The Bio-Z® platform grew out of peer-reviewed research by ParaNano's founders and university partners on bacterial lipase-responsive, color-changing electrospun nanofibers. These are laboratory studies; ParaNano's products remain investigational.

*Peer-reviewed academic research underpinning the Bio-Z® platform. Findings describe laboratory studies and do not establish clinical performance of ParaNano's investigational products.

Intellectual property

A comprehensive IP portfolio behind Bio-Z®.

The Bio-Z® platform is protected by exclusively licensed patents spanning the manufacturing process, fabrication machine, fiber composition, and product lines.

University of Central Oklahoma

Electrospinning

Exclusive license

GrantedUS 10,640,888 · US 10,876,223 · US 10,995,425 · US 11,208,735 · US 11,913,139 · US 12,252,813 · US 12,270,126PendingUS 19/018,351 · US 19/059,588 · US 19/079,737
University of Manitoba

Bio-responsive nanofiber

Exclusive license

GrantedUS 10,973,775 · US 11,911,521PendingUS 17/487,285 · US 18/129,212 · US 19/048,015 · US 63/734,306
Scope & limits

What bench data does, and doesn't, tell us.

What it establishes

How the Bio-Z® material behaves under controlled laboratory conditions: that it responds to bacterial lipase activity, selectively, and produces a clear, qualitative, naked-eye color change.

What it does not establish

Bench and in-vitro data do not demonstrate clinical performance, and do not detect, diagnose, confirm, or quantify infection. The products are investigational and not cleared or approved. Clinical validation is ongoing.

*This device has not been FDA-cleared or approved for in vitro diagnostic use and is not available for sale. Describes a device under development. Based on laboratory (bench) testing; laboratory results may not predict clinical performance. Findings summarized from ParaNano internal validation reports. Forward-looking statements about ongoing validation are not guaranteed.

News & newsletter

The journey toward a healthier tomorrow.

At ParaNano, we're pioneering the future of wound care, rooted in innovation, compassion, and a deep commitment to patient outcomes. Explore our latest milestones and features.

All news

Latest from ParaNano.

Updates, milestones, and features from the ParaNano team.

November 21, 2024 · ParaNano Team

ParaNano secures $500K OCAST grant to advance Bio-Z® innovation

ParaNano secured a $500,000 grant from the Oklahoma Center for the Advancement of Science and Technology (OCAST) to support continued development of its Bio-Z® color-changing nanofiber technology.

*Grant support is not an FDA endorsement.

June 18, 2024 · ParaNano Team

Featured in the OCAST Annual Report as “Innovation in Action!”

ParaNano Wound Care, LLC was highlighted in the OCAST Annual Report under “Innovation in Action,” recognizing the company's Oklahoma-based materials-science work in wound care.

April 15, 2024 · ParaNano Team

MedTech Minis, Episode 3: ParaNano Wound Care

ParaNano was featured in Episode 3 of the MedTech Minis series, introducing the company and the Bio-Z® platform behind its wound-care products.

Newsletter

Stay in the loop.

Join us for updates, breakthroughs, and milestones as they happen.

Subscribe for updates

We'll only email about meaningful milestones.

About ParaNano

Advancing materials science for wound care.

ParaNano, Inc. is a medical device company developing passive, color-changing nanofiber technology built on the Bio-Z® platform. Its products are investigational and under development.

Who we are

Oklahoma-built medtech, advancing from the lab.

ParaNano, Inc. is an Oklahoma-based medical device company developing its proprietary Bio-Z® platform of color-changing nanofiber technologies. Founder-led by CEO Chelsea Luxen and CTO Maurice Haff, the company uses electrospinning manufacturing to transform color-changing nanofibers into passive, non-electronic smart-material dressings.

The platform underlies two products in development: WoundCue™, an investigational colorimetric product built on Bio-Z® for healthcare settings, and WoundSentinel™, a field/military variant (TRL-6) designed for austere environments. Chronic wounds carry a substantial clinical and economic burden in the U.S., a problem space ParaNano's technology is being developed to help address.

ParaNano's development is backed by three Defense Health Agency (DHA) SBIR contracts and is based in Oklahoma City, with nanofiber manufacturing at the Meridian Technology Center in Stillwater, Oklahoma.

*Funding and program participation are not an FDA endorsement or clearance.

Headquarters
Oklahoma City, Oklahoma
Defense funding
$4.75M across three DHA SBIR contracts
Manufacturing
Electrospun nanofiber, Meridian Technology Center, Stillwater, OK

Our mission

Advance materials science for better insight in wound care, a passive, non-electronic color change, without wires or power.

Our approach

Evidence first. We build in-vitro and clinical understanding alongside careful, compliant claims, not ahead of them.

Our partners

Advanced in collaboration with JLABS, OCAST, the University of Manitoba, BioNTX, the Blue Knight™ program, and the DHA.

*Grant support and affiliation are not an FDA endorsement.

Our team

The people behind ParaNano.

A team spanning materials science, operations, regulatory, and clinical practice.

Leadership

Chelsea Luxen
CEO & Co-founder · Board Member

Chelsea Luxen

A decade-plus turning breakthrough research into commercial medtech; leads ParaNano’s vision, financing, and commercialization.

Read bio
Maurice Haff
CTO & Co-founder · Board Member

Maurice Haff

40+ years in entrepreneurship and MedTech; registered patent agent and inventor behind the platform’s patents.

Read bio
Peter Rock
Chief Operating Officer

Peter Rock

Fractional CFO/COO and advisor across life-science and medical-device start-ups: finance, operations, and compliance.

Read bio

Board of Directors

Rod Whitson
Chairman of the Board

Rod Whitson

Entrepreneurial operating-system implementer and executive leader with deep experience scaling growth-stage life-science and technology companies.

Read bio
Lora Spencer
Board Member

Lora Spencer, Esq.

Chief Legal Counsel for Mechanical Circulatory Support at Medtronic, with deep healthcare-technology legal and governance expertise.

Read bio

Team

Derby Whitefield
Director of Manufacturing

Derby Whitefield, MBA

Mechanical engineer leading manufacturing-technology development and scale-up for the Bio-Z® platform.

Read bio
Kelley Dowd
Director of Operations

Kelley Dowd

Builds the operational backbone behind ParaNano’s pilot production and program delivery.

Read bio
Farinaz Jonidi Shariatzadeh
Lead Researcher

Farinaz Jonidi Shariatzadeh, PhD

Biomaterials scientist leading research and development of ParaNano’s colorimetric wound-monitoring platforms.

Read bio
Mark Sakrison
VP, Business Development
ARM Venture Solutions

Mark Sakrison

Senior medtech executive with 40+ years across device and technology companies, driving business development.

Read bio
Andy Cibotti
Director of Sales

Andy Cibotti

Leads commercial strategy and sales channels across federal and DME markets.

Read bio
Janice Braddock
Director of Quality

Janice Braddock

Oversees quality systems and documentation across ParaNano’s development programs.

Read bio
Jazmine Ivery
Office Manager & Communications Coordinator

Jazmine Ivery, BA

Daily operations and internal communications.

Read bio

Advisors & inventors

Song Liu
Inventor

Song Liu, PhD

Professor of Biosystems Engineering at the University of Manitoba whose polymer and nanofiber research underpins the Bio-Z® platform.

Read bio
Sarvesh Logsetty
Inventor

Sarvesh Logsetty, MD

Burn and trauma surgeon and Professor of Surgery at the University of Manitoba; directs the Manitoba Firefighters Burn Unit.

Read bio
Ronald Scott
Wound Care Advisor

Ronald Scott, MD

Clinical advisor on how the Bio-Z® platform could fit alongside wound assessment.

Our Partners

UMass Lowell University of Central Oklahoma University of Manitoba OSU New Product Development Center National Science Foundation / NSF I-Corps ARM Venture Solutions Veterans Way Prime Path Medtech
“The Bio-Z® technology could direct the clinician, at the point of care, to take appropriate steps in a timely fashion for better outcomes.”
Ronald Scott, MD  ·  Wound Care Advisor

Advisor opinion; forward-looking. This device has not been FDA-cleared or approved for in vitro diagnostic use and is not available for sale. Describes a device under development. Forward-looking; development and regulatory outcomes and timing are not guaranteed.

Contact us

Let's talk wound care.

Whether you're a clinician, a health system, a defense program, or a prospective partner. Tell us what you're looking for and the ParaNano team will follow up.

What we can help with

Reach the ParaNano team.

  • Product information for WoundCue™ and WoundSentinel™
  • Clinical questions & in-service materials
  • Defense health & prolonged field care inquiries
  • Research, pilot, and partnership opportunities

ParaNano products are investigational and not yet cleared or approved for clinical use. We can describe intended-use scope in a direct conversation.